經濟部能源局節能標章連絡我們
最新消息 相關條文 問與答 廠商登入 下載申請表 已核准產品 已註銷產品
相關條文
分享 : 推到facebook 推到plurk 推到twitter
字型大小: 字體:[增加|減小]
|回列表||往前一則
項目標題圖示 Revised Refrigerator power consumption standard and power efficiency grade labeling, method, and inspection method regulation
有相關檔案

Revised Refrigerator power consumption standard and power efficiency grade labeling, method, and inspection method regulation
Subject: Revise and combine the refrigerator energy efficiency standard and refrigerator power consumption and its energy efficiency grade labeling, method, and inspection method into refrigerator power consumption standard and power efficiency grade labeling, method, and inspection method regulation and goes into effect beginning January 1st, 2018.
Base: Item 14-4 of the “Energy Management Act”
Publications:
1. The refrigerators of this regulation are those compliant with CNS 2062 and contained in list of products requiring inspection by the Bureau of Standards, Metrology & Inspection (BSMI), M.O.E.A.
2. Test and calculate actual energy factor (E.F.) values of refrigerator according to CNS 2062 and round energy factor value to the nearest tenth.
The actual energy factor ratings shall be greater than standard value (appendix 1) and 95% of product rated value.
3. Refrigerator manufacturer or importer shall apply for its energy efficiency grade labeling management system (Management System hereafter) account and password with the central competent authority with the following documents:
3.1 Energy efficiency grade labeling management system account and password application form (appendix 2).
3.2 Company or business registration documents
4. The supplier shall file for refrigerator energy efficiency grade labeling with the central competent authority with the following documents:
4.1 Refrigerator energy efficiency grade labeling registration form (appendix 3)
4.2 Refrigerator merchandise verification license or merchandise type certificate and upload its electronic copy (color scan) to the Management System
4.3 Photo copy or electronic file in DVD ROM of safety test report and energy efficiency test report by third party labs certified by BSMI; the hard copy of the report shall be stamped with company chops.
4.4 In case the model number given in the said test report differs from the one for energy efficiency grade labeling yet is contained in the same merchandise verification license or merchandise type certificate the supplier shall submit energy electric efficiency compliance type statement (appendix 4)
5. The central competent authority shall approve the subject product's energy efficiency grade according to the energy factor value given in the said test report based on the refrigerator energy efficiency grading standard (appendix 5).
6. Manufacturer or importer of refrigerator shall attach energy efficiency grade label (figure 1) to visible location at front of product or its manual; attach or display energy efficiency grade labeling to visible location at front of product when merchandising or retailing refrigerator.
The energy efficiency grade labeling shall conform to specification given in figure 1 and present in color and shall not make it unidentified by consumers in any method. The energy efficiency grade labeling may be magnified proportionally.
7. Product catalogue used by supplier at showroom or retailing location shall display energy efficiency grade labeling (figure 2) along with its refrigerator image. For product information of refrigerator expressed in texts or tables, the energy factor ratings and energy efficiency grade shall be added.
8. Refrigerator manufacturer or importer shall re-apply for refrigerator energy efficiency grade labeling in case of any of the following:
8.1 Change in design which may have impact on energy efficiency grade.
8.2 Change in model number.
9. The supplier shall report units of individual models of refrigerator sold last year at the Management System before end of each February.
10. The central competent authority shall carry out annual energy efficiency spot check by specifying models and quantities of product for random testing. The supplier shall submit subject products to given labs for testing in given period. Actual energy factor values of products under test shall be equal to or greater than 95% of their rated value and compliant with refrigerator power consumption and energy efficiency grade standard.
Suppliers who failed the test may subject to another test as required by the central competent authority. This test shall have twice as many products of the same model in first test and at the expenses of the supplier.
The supplier shall subject to penalties given in item 21 and 24 of the Energy Administration Act and revoke its energy efficiency grade labeling certificate in case it failed to run the 1st and 2nd (if needed) spot check or the 2nd test has any one product failed the test. Suppliers who stopped the manufacturer or import of products and in a position unable to carry out energy efficiency test shall be exempted from this after the central competent authority approved and withdrew the energy efficiency grade labeling.
The central competent authority shall publicize the said information in the Management System according to the Consumer Protection Act.
11. The sampling quantity shall be determined by the following rule: every 4000 units made or imported last year shall sample one unit for spot check, models of population less than 4000 shall sample one as well. The central competent authority may adjust test model and quality as required.
有相關檔案
Revised Refrigerator Freezers-Appendix.pdf
回列表

 

 

 



累計瀏覽人數:04669020
    
2017/5/29瀏覽人數:02456
經濟部 能源局 工研院
政府網站資料開放宣告
※ 建議使用 IE 9.0 以上瀏覽器,在 1024 * 768 螢幕模式下瀏覽   能源效率諮詢電話 02-8772-8082 轉 591 或 595